Railway Cables | ||||||||||
|
0.45/0.75KV Single Core Standard Wall Traction Cables
Application
Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles
for connecting fi xed and moving parts.
Standards
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
Conductors
Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.
Insulation
Electron beam crosslinkable standard wall LSZH compound
Optional
FRA-SW-0.75S (Sheathed); FRA-SW-0.75S-OS (Screened & sheathed)
FRA-SW-0.75SU-FR (Fire resistant & Unsheathed)
Electrical Characteristics at 20℃
Nominal Conductor Cross Section | mm² | 1.0 | 1.5 | 2.5 | 4.0 | 6.0 | 10 | 16 |
---|---|---|---|---|---|---|---|---|
Maximum Conductor Resistance | Ω/km | 20 | 13.7 | 8.21 | 5.09 | 3.39 | 1.95 | 1.24 |
Voltage Rating | KV | 0.45/0.75 |
Mechanical and Thermal Properties
Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)
Temperature Range:-40℃ to +120℃
Dimensions And Weight
Cable Code | No. of cores& Nominal
Conductor Cross Sectional Area No.×mm² |
Nominal Diameter of Strands mm |
Nominal
Insulation Thickness mm |
Nominal
Overall Diameter mm |
Nominal
Weight kg/km |
---|---|---|---|---|---|
FRA-SW-0.75SU-1G1 | 1×1.0 | 32/0.2 | 0.8 | 3.9 | 28 |
FRA-SW-0.75SU-1G1.5 | 1×1.5 | 30/0.25 | 0.8 | 4.2 | 34 |
FRA-SW-0.75SU-1G2.5 | 1×2.5 | 50/0.25 | 0.8 | 4.6 | 41 |
FRA-SW-0.75SU-1G4 | 1×4.0 | 56/0.3 | 0.8 | 5.2 | 64 |
FRA-SW-0.75SU-1G6 | 1×6.0 | 84/0.3 | 0.9 | 6.4 | 93 |
FRA-SW-0.75SU-1G10 | 1×10.0 | 80/0.4 | 0.9 | 7.5 | 141 |
FRA-SW-0.75SU-1G16 | 1×16.0 | 126/0.4 | 1.1 | 8.6 | 203 |